Possible reasons:
1. Over-Discharge Protection
Benchmark:
Single cell <2.5V
Battery pack<10V
Solution: Disconnect loads from battery and recharge the battery with 14.6V 20A charger to override the protection and regain power.
2. Voltage Compatibility Issues
The battery matches with the using device's peak voltage's requirment but the running voltage's requirment exceeding the battery's specification
Solution: Fully recharge the battery with 14.6V 20A LiFePO4 charger and test it with a slight load and see if issues recurred. If there is no issues with the testing device, it is confirmed compatibility issues with previous using devices.
Was this article helpful?
That’s Great!
Thank you for your feedback
Sorry! We couldn't be helpful
Thank you for your feedback
Feedback sent
We appreciate your effort and will try to fix the article